22
The different functions of the «BASIC SETTINGS» screen: (next)
• Length counter. display (cm):
Display the measured length of linen.
- 0 : Length measure display deactivated.
- 1 : Length measure display activated.
Factory value
0
• 3rd Cross Fold activat.:
Activation / Deactivation of the 3
- 0 : 3
cross fold deactivated.
rd
- 1 : 3
cross fold activated.
rd
Factory value
1
• Parameters saving:
Backup electric boards parameters of the machine.
- 0 : Saving deactivated.
- 1 : Current saving.
Factory value
0
• CMIS: Machine adress:
Selection of the address of machine in CMIS mode.
Factory value
0
• CMIS: Machine type:
Selection of the type of machine (length of machine) in CMIS mode.
- 19 : IC4 48119 FFS
- 25 : IC4 48125 FFS
- 32 : IC4 48132 FFS
Factory value
32
• DIAMMS maximum speed:
Selection of the maximum speed of DIAMMS.
Factory value
11.3
24
ELECTROLUX ITS Screens
Minimum value
0
cross fold.
rd
Minimum value
0
Minimum value
0
Minimum value
0
Minimum value
19
Minimum value
3.5
Maximum value
1
Maximum value
1
Maximum value
1
Maximum value
127
Maximum value
32
Maximum value
11.3
Service
Manual
Incrementing
1
Incrementing
1
Incrementing
1
Incrementing
1
Incrementing
19 or 25 or 32
Incrementing
0.1