Operation - Electrolux IC4 4819 FFS Service Manual

Feeder ironer folder & stacker
Table of Contents

Advertisement

23
Ventilation and motion of the machine

Operation

The ventilation of the machine and the motion of the ironing cylinder are activated when the
machine is ON after a verifi cation of the security chains.
Controlled by the ELECTROLUX ITS, the KM1 contactor supplies the A1 converter and the M12
fan motor and the KM2 contactor supplies the M2 fan motor.
The M12 fan motor is mounted in standard only on the machines with gas heating and allow to
cool down the right casing of the machine.
In order to control the variations speed of the ironing, the M1 motion motor which drives the
ironing cylinder is controlled via the A1 converter.
Power supply
3 phases
Q0
400
400
ARU
* ARU = Security chain, emergency push button
2
Q4
KM2
230
Q1
T1
230
M1
F2
B3
X108
X109
24
M2
Q3
230
Q2
KM1
L1, L2
U
A1_Converter
V
W
T1, T4
B5
B2
X110
X111
X115
X112
KM1
KM2
M12
T2
X118
X129
X117
A1_BASE
04102011/GB
06.2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic4 4825 ffsIc4 4832 ffs

Table of Contents