Electrolux IC4 4819 FFS Service Manual page 148

Feeder ironer folder & stacker
Table of Contents

Advertisement

22
The different functions of the «MACHINE CONFIGURATION»: (next)
• Stacker PCB activation:
Activation / Deactivation of the COM connection of STACKER board.
Factory value
1
• Temperature in °F:
Selection of the temperature unit: 0 = degrees Celsius
Factory value
0
• Mains frequency:
Selection of the mains frequency: 50 Hz or 60 Hz.
WARNING: Don't forget to set the main frequency of the machine (50 or 60 Hz)
Factory value
50
• Ge=1, El=2, Se=3, Ga=4:
Selection of the type of heating:
Factory value
according to
the type of heating
• Automatic re closing:
Factory value
1
• Memory reset:
Restricted access only to the factory.
Factory value
0
• Test program:
Activation / Deactivation of the automatic operation of the machine in order to control
the electric and mechanical parts. This function is only activated when the machine is in
motion.
Factory value
0
32
ELECTROLUX ITS Screens
Minimum value
0
Minimum value
0
before any change of folds tables.
Minimum value
50
and
Minimum value
1
Minimum value
0
Minimum value
0
Minimum value
0
Maximum value
1
1 = degrees Fahrenheit
Maximum value
1
Maximum value
60
Ge : Europe gas,
El : Electric,
Se : Steam
Ga : Australia gas.
Maximum value
4
Maximum value
1
Maximum value
1
Maximum value
1
Service
Manual
Incrementing
1
Incrementing
1
Incrementing
10
Incrementing
1
Incrementing
1
Incrementing
1
Incrementing
1
04102011/GB
17.2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic4 4825 ffsIc4 4832 ffs