Defining The Communication Settings Packet - Avery Dennison Monarch 9419 Reference Manual

Hide thumbs Also See for Monarch 9419:
Table of Contents

Advertisement

D e f i n i n g t h e C o m m u n i c a t i o n S e t t i n g s P a c k e t
Use the communication settings packet (F) to set the baud rate, word length, stop bits, parity,
and flow control for serial communications. To set parallel communications, see "Using Parallel
Communications."
Changing the communication settings takes approximately two seconds. Communications sent
during this interval will be lost. Make sure the host communication values match the values on
the printer and the host is capable of communicating at the selected printer speed.
Do not add any characters, such as a carriage return/line feed, in the communication settings
packet or communications errors may occur.
Syntax
{I,F,baud,word_length,stop_bits,parity,flow_control | }
F1. F
F2. baud
F3. word_length
F4. stop_bits
F5. parity
F6. flow_control
Example
{I,F,3,1,0,0,1 | }
Uses 9600 baud, an 8-bit word length, one stop bit, no parity, and the DTR mode.
2-12 Packet Reference Manual
Communication Settings Packet
Baud Rate. 3 is the default. Options:
0
1200
1
2400
2
4800
3
9600
Word Length. 1 is the default. Options:
0
7-bit word length
1
8-bit word length
Stop Bits. 0 is the default. Options:
0
1-stop bit
1
2-stop bits
Parity. 0 is the default. Options:
0
None
1
ODD parity
2
EVEN parity
Flow Control. 1 is the default. Options:
0
None
1
DTR
Note:
If using the COPY command to download formats, set Flow Control
to DTR (not XON/XOFF).
4
19200
5
38400
6
57600
7
115200
2
(CTS)
3
XON/XOFF