D e f i n i n g B a r C o d e F i e l d s
Each bar code field requires a separate definition.
Syntax
B,field#,# of char,fix/var,row,column,font,density,height,
text,alignment,field rot |
B1. B
B2. field#
B3. # of char
Bar Code
Codabar (NW7)
Code 16K
Code 39 (w/ or w/o CD) or MOD43
Code 93
Code 128
Data Matrix
EAN8
EAN8+2
EAN8+5
EAN13
EAN13+2
EAN13+5
EAN13+Price CD
Interleaved 2 of 5 or
Interleaved I 2 of 5 with Barrier Bar
MaxiCode
MSI
PDF417
POSTNET™
Bar Code Field.
Unique number from 1 to 999 to identify this field. 1 is the default.
Maximum number of characters. If the bar code uses a check digit, allow
an extra character for the check digit. The actual maximum number of
characters is limited by the size of the label and bar code density. Range:
0 to 2710. 30 is the default.
Number of Characters
0 – 2710
0 – 2710
0 – 2710
0 – 2710
0 – 2710
0 – 2710 numeric; 0 – 2335 alphanumeric
8
10
13
13
15
18
13
0 - 2710
0 to 93 (alphanumeric)
0 to 128 (numeric)
0 – 14
0 – 2710
9 or 11