Rf Module; Maximum Ratings; Rf Frequency Plan - Nokia NSE-6 SERIES Service Manual

Cellular phone
Table of Contents

Advertisement

NSE–6
System Module

RF Module

This RF module takes care of all RF functions of the engine. RF circuitry
is located on one side (B–side) of the 6 layer PCB. PCB area for the RF
circuitry is about 40 x 50 mm.
EMC leakage is prevented by using a metal B–shield, which screens the
whole engine. The metal gasket is used between the PCB and the
shield. The baseband circuitry is located on the A–side of the board,
which is shielded with a metallized frame and ground plane on UI–board.

Maximum Ratings

Parameter
Battery voltage, idle mode
Battery voltage during call, highest power level
Regulated supply voltage
Voltage reference
Operating temperature range

RF Frequency Plan

CRFU_1
935–960
MHz
LO–
buffers
890–915
MHz
Page 3 – 46
6.0 V
5.0 V
2.8 +/– 3% V
1.5 +/– 1.5% V
–10...+55 deg. C
1st IF 71 MHz
2nd LO
58 MHz
f
f/2
1006–
UHF
1031
PLL
MHz
TX IF 116 MHz
f
f/2
Technical Documentation
Rating
SUMMA
2nd IF 13 MHz
f
232
MHz
f/2
VHF
PLL
13 MHz
VCTCXO
Original 08/98
PAMS