Technical Documentation
The last value on the display is signal power difference between I and Q
branch. The numbers are shown in 0.1dB accuracy. The error messages,
"OUT OF RANGE", are shown only if the SNR and/or amplitude differ-
ence values are not acceptable.
Signal/Noise radiobutton (ALT+S/ALT+N):
When buttons are pressed, the RX I and Q burst data is asked, text "SIG-
NAL MEASURING..." or "NOISE MEASURING..." will come to the mea-
surement group window. The power level value should be –92 dBm dur-
ing signal measurement.
When signal data is received, distance to clipping signal level is shown as
dBs on the display. When either signal or noise measurement results are
received "MEASURING" text is removed and measurements are updated
to screen. When both measurements (signal and noise) are done at least
once, the signal to noise relation and difference are also shown on the
display.
When exit is made, the next selections are set to the values which were
selected before this adjustment.
– Operation mode
– AGC value
IR Test... command
NOTE! Applies only to phones equipped with Infrared ports.
Activation
Alt, E,I
Command is used for making IR module test. Function opens IR Test dia-
log:
Dialog mode: modal
IR Test dialog has following items:
Result box:
Test (ENTER) button:
Close button:
Original 08/98
Status Bar Text
IR module test
Result can be OK/FAILED
Starts IR Test.
NSE/M–1/3/6
Service Software Instructions