Nokia NSE-6 SERIES Service Manual page 153

Cellular phone
Table of Contents

Advertisement

PAMS
Technical Documentation
Dialog mode: modal
Call Simulation dialog has following items:
TX Power Level edit box (ALT+T):
All power levels can be selected. This updates same parameter as TX
Power Level in the RF Controls dialog. Note that TEST value cannot be
selected. If TEST value was in use when Call simulation menu selected,
power level is changed to smallest value.
Channel edit box (ALT+C):
This tells the normal operating RF channel number. Normal GSM/PCN
channel numbers can be selected. Same channel is used both for trans-
mission and receiving. This updates same parameter as Channel in the
RF–Controls dialog.
Channel 1,2,3,4,5,6 edit box (ALT+1,2,...):
Channels for monitoring are specified with these six selections. All GSM/
PCN channel numbers can be used. If more than one selection has same
number, the monitoring channel list (neighbour list) will have less than 6
selected channels. The minimum number of monitoring channels is one
(all channels have same value). The monitoring channel can also have
same value as normal operating channel.
The first monitoring channel updates same parameter as Monitoring
Channel in the RF–Controls dialog.
Apply button (ALT+A):
Validates and sends entered data to ME.
Set Defaults button (ALT+S):
Sets current values as default Call Simulation values.
Get Defaults button (ALT+G):
Gets default Call Simulation values as current values.
Original 08/98
NSE/M–1/3/6
Service Software Instructions
Page 51