Operation

3.14 Travel interlock

A
Fig. 29: Travel interlock key
0
Fig. 30: Travel interlock key
3-18
Scope of delivery
A: starting key (blue, 2 pieces)
B: master key (red)
Important
Keys can be coded or deleted only with the master key. A new travel interlock
B
must be installed if the master key is lost.
Coding keys
1
Insert the master key in the starter and turn it to position 1 for a maximum 5 seconds.
1
2
Remove the master key.
3
Turn the keys requiring coding to position 1 within 15 seconds, for at least one second.
The key is registered.
Coding is automatically interrupted if no key is coded within 15 seconds.
Coding can be performed for a maximum 10 keys.
Deleting a key
If a coded key is lost, all keys have to be deleted and recoded.
1
Insert the master key in the starter and turn it to position 1 for at least 20 seconds.
The coded keys are deleted now. New or existing keys have to be recoded.
BA 1001/1501/2001 us – Edition 3.3 * * 12001b330.fm