Important Information On The Use Of Biodegradable Oil - Wacker Neuson 1001 Operator's Manual

Dumper
Table of Contents

Advertisement

Maintenance

Important information on the use of biodegradable oil

5-24
• Use only the biodegradable hydraulic fluids which have been tested and approved by
Wacker Neuson GmbH. Always contact Wacker Neuson for the use of other products
that have not been recommended. In addition, ask the oil supplier for a written decla-
ration of guarantee. This guarantee is applicable to damage occurring on the hydraulic
components that can be proved to be due to the hydraulic fluid.
• Use only biodegradable oil of the same type for adding oil. In order to avoid misunder-
standings, a label providing clear information is located on the hydraulic oil reservoir (next to
the filler inlet) regarding the type of oil currently used! Replace missing labels!
The joint use of two different biodegradable oils can affect the quality of one of the oil types.
Therefore, ensure that the remaining amount of initial hydraulic fluid in the hydraulic system
does not exceed 8 % when changing biodegradable oil (manufacturer indications).
• Do not add mineral oil – the content of mineral oil should not exceed 2 % in order to
avoid foaming problems and to ensure biological degradability.
• When running the machine with biodegradable oil, the same oil and filter replacement
intervals are valid as for mineral oil
(overview) on page 5-39.
• Always have the condensation water in the hydraulic oil reservoir drained by a Wacker
Neuson service center before the cold season. The water content may not exceed
0.1 % by weight.
• The instructions in this Operator's Manual concerning environmental protection are
also valid for the use of biodegradable oil.
• If additional hydraulic attachments are installed or operated, use the same type of
biodegradable oil for these attachments to avoid mixtures in the hydraulic system.
Subsequent change from mineral oil to biodegradable oil must be performed by a Wacker
Neuson service center or by your Wacker Neuson dealer
– see chapter 5.16
Maintenance plan 2001
BA 1001/1501/2001 us – Edition 3.3 * * 12001b520.fm

Advertisement

Table of Contents
loading

This manual is also suitable for:

15012001

Table of Contents