Appendix A: Audio Option Specifications; Automatic Audio Test Specifications; Table A-1: O.33 Automatic Audio Test Measurement Specifications - Tektronix VM700T User Manual

Ideo measurement set option 40/41/42 audio measurements
Hide thumbs Also See for VM700T:
Table of Contents

Advertisement

Appendix A: Audio Option Specifications

Automatic Audio Test Specifications

Table A-1: O.33 Automatic Audio Test Measurement Specifications

a
Measurement
b
Insertion Gain Error
Sweep Gain (Min and Max)
THD + N (at 1020 Hz)
2nd Harmonic (at 60 Hz)
3rd Harmonic (at 60 Hz)
c
Crosstalk (into channel)
Test Level:
+6 dBu
0 dBu
–6 dBu
d
SNR (unweighted)
Test Level:
+6 dBu
0 dBu
–6 dBu
d,e
SNR (weighted)
Test Level:
+6 dBu
0 dBu
–6 dBu
Max Compandor Error (rise/fall)
Gain Difference
Phase Difference
a
Assumes insertion gain is within
b
The measurement range specification assumes that the input level is within
configuration. The actual O.33 test level range is –6 dBu to +14 dBu.
c
The value for other test levels can be calculated from the formula (–60 – Test Level).
d
Measured with Quasi–Peak response as per CCIR 468-4 recommendation. The measurement range can be determined
from the formula (70 + Test Level).
e
Weighting filter as per CCIR 468-4 recommendation.
VM700T Option 40/41/42 Audio Measurements User Manual
Range
6 dB
12 dB
0.03% to 70%
0.03% to 70%
0.03% to 70%
–66 dB to 0 dB
–60 dB to 0 dB
–54 dB to 0 dB
10 dB to 76 dB
10 dB to 70 dB
10 dB to 64 dB
10 dB to 76 dB
10 dB to 70 dB
10 dB to 64 dB
6 dB
12 dB
–180 to 180
6 dB.
Accuracy (Includes Flatness)
0.2 dB
0.1 dB
10% 1 digit
10% 1 digit
10% 1 digit
1 dB
1 dB
2 dB
0.2 dB
0.2 dB
1
6 dB of the O.33 test level in the audio
A-1

Advertisement

Table of Contents
loading

Table of Contents