Appendix B: Verification Procedure

Table B-1: Test Equipment Required for Verification Procedures

Equipment
Sine-wave generator
Adapter cable, three banana
plug to one male XLR, 2 re-
quired
Female-XLR-to-male-mini-XLR
adapter cable, 2 required
Dual female XLR to single male
XLR connector
Dual male XLR to single female
XLR connector (mates with 2
female-XLR-to-male-mini-XLR
adapter cables)
Dual female XLR to DB-37
female adapter cable.
a
The TEGAM SG5010 sine-wave generator requires a TEGAM TM500 or TM5000 series power module.
B-2
Minimum Specification
Frequency accuracy, 0.01%;
level flatness (20 Hz to 20 kHz),
0.05 dB; level accuracy (20 Hz
to 20 kHz), 0.2 dB; residual
distortion, 0.0010% (–100 dB)
XLR connectors must be wired
to current AES recommenda-
tions: pin 1 ground, pin 2 hot,
pin 3 cold
Supplied with VM 700T
Option 40
XLR connectors must be wired
to current AES recommenda-
tions: pin 1 ground, pin 2 hot
(+), pin 3 cold (–) (See
Figure 1–7 on page 1–12 for
XLR connector pin locations.)
XLR connectors must be wired
to current AES recommenda-
tions: pin 1 ground, pin 2 hot
(+), pin 3 cold (–)
XLR connectors must be wired
to current AES recommenda-
tions: pin 1 ground, pin 2 hot,
pin 3 cold. See Figure 2–17 on
page 2–31 for pin outs of the
VM700T female DB-37 connec-
tor.
NOTE. Before performing the level accuracy procedure, Verify the sine-wave
generator level at 120 Hz by measuring with an accurate AC voltmeter such as a
HP 3458A Digital Voltmeter. You may also use an AC voltage calibrator such as
a Fluke 5700A for this measurement. Verify that the sine-wave generator can
meet the amplitude accuracy specifications listed in Table B-1.
VM700T Option 40/41/42 Audio Measurements User Manual
Purpose
Required for all Option 40 and
Option 41 verification proce-
dures
Connects sine-wave generator
to adapter cable supplied with
VM700T Option 40
For level accuracy, level flat-
ness, frequency, and phase
measurement accuracy proce-
dures
In distortion measurement
procedure, connects two sine-
wave generators to one Op-
tion 40 input
In frequency and phase mea-
surement accuracy procedure,
used to apply signal from one
sine-wave generator to both
Option 40 inputs
Used to connect the sine-wave
generator to the triple VM 700T
audio inputs of Option 41
Example
TEGAM SG5010 (two are
needed to check distortion
measurement accuracy)a
E-Z-Hook #5023-xx or equiva-
lent
Supplied with Option 40
Fabricated by user
Fabricated by user
Fabricated by user
(DB-37 connectors are included
with Option 41)