Audio Monitor; Figure 2-3: The Audio Monitor Phase Display (Soundstage Format) - Tektronix VM700T User Manual

Ideo measurement set option 40/41/42 audio measurements
Hide thumbs Also See for VM700T:
Table of Contents

Advertisement

Operating Basics

Audio Monitor

2–6
The Audio Monitor measurement displays the audio levels and phase relation-
ships of a two-channel audio signal. Figure 2–3 shows the Audio Monitor phase
display.
Figure 2–3: The Audio Monitor phase display (soundstage format)
The phase display plots audio input signals in a Lissajous phase display. This
display may be configured to show the signals in either soundstage (the default)
or X-Y (oscilloscope) format. The display also provides a bar graph of left
channel, right channel, and left plus right channel sound levels. The scales of the
bar graph display may be configured for Nordic PPM or DIN 45406 dB, or VU
units. For information on configuring the phase display, see Configuring the
Audio Option beginning on page 1–1.
The VM700T Configuration directory allows you to configure these Audio
Monitor functions:
Level meter scales: DIN 45406 or Nordic ppm dB or VU
equivalent dBu setting for 0 dB scale readout
type of Lissajous display: soundstage or x/y (oscilloscope)
VM700T Option 40/41/42 Audio Measurements User Manual

Advertisement

Table of Contents
loading

Table of Contents