Alarms/diagnostic messages
5.1 Status and error displays
ST/OL (STATE/OVERLOAD) LED
Table 5- 2
Status display ST/OL
ST/OL LED
Operation
On
STOP
Off
Overload
Flashes
at 3 s
MAN (MANUAL) LED
Table 5- 3
Status display MAN
MAN LED
Manual local mode deactivated
Off
Manual local mode activated
On
PWR (POWER) LED
Table 5- 4
Status display PWR
PWR LED
Supply voltage not present or too low
Off
Supply voltage present
On
LED F-DI for fail-safe motor starters
Table 5- 5
Status display F-DI
LED F-DI
LOW level at the fail-safe digital input on the
BaseUnit in the case of a fail-safe motor starter.
Off
HIGH level at the fail-safe digital input on the
BaseUnit in the case of a fail-safe motor starter.
On
112
Motor operating state
Meaning
Meaning
Meaning
Meaning
ON command for motor active
The motor is switched off.
It is not known whether the motor is still rotating or not.
The thermal motor model or device protection model
has tripped.
Remedy
-
-
Remedy
Check the supply voltage.
-