Example 1: Input 1 signal = retentive/edge-triggered
Example 2: Input 1 signal = non-retentive
Motor starter (3RK1308-0**00-0CP0)
Manual, 12/2016, A5E34821005002A/RS-AB/002
The motor is switched on by "Motor CW".
Motor is switched on by "Motor CW", then switched off by the rising edge at digital input 1
(parameterized to input action 1 = Quick Stop). By revoking the "Motor CW" command, the
Quick Stop function is reset.
Motor is switched on by "Motor CW", then switched off by the rising edge at digital input 1. By
setting Disable quick stop, the Quick Stop function is reset and the motor runs "CW" again until
the "Motor CW" command is revoked.
Motor is switched on by "Motor CW", then switched off by the rising edge at digital input 1. By
setting Disable quick stop, the Quick Stop function is reset and the motor runs "CW" again.
Although the static digital input signal 1 (DI2) is still present, the motor continues to run and is
only reset by revoking the "Motor CW" command.
Reason: The input action is edge-triggered.
Motor is switched on by "Motor CW" and continues to run uninterrupted since Disable quick
stop continuously overwrites the edges of the signal of digital input 1 (DI2).
The motor is switched on and off by "Motor CW".
The motor is switched on by "Motor CW", then switched off by the level at digital input 1
(parameterized with input action 1 = Quick Stop). The Quick Stop function is reset by Disable
quick stop. The motor is switched on again since "Motor CW" is still active.
The motor is switched off by the level at digital input 1. The "Quick Stop" function is reset by
setting "Disable quick stop". As the level "Motor CW" is still active, the motor runs "CW" again
until the "Disable quick stop" command is revoked.
Motor is switched on by "Motor CW", then switched off by the level at digital input 1. While the
"Quick Stop" function is active, the motor remains switched off and starts up again when "Quick
Stop" is revoked until "Motor CW" is switched off.