Technical Specifications
Mains « Harmonics » Analysis Mode
2-page display of "Harmonics"
Even harmonics
Odd harmonics
1-page display of "Harmonics"
Fundamental Frequency of the
signal analyzed
Measurement accuracy
Level of Fundamental
Level of Harmonics
Harmonic Distortion
« Recorder » Mode
Recording period
Sampling rate
Fault capture
Triggering
Trigger event period
Min. value of the period
Max. value of the period
Display
Vertical, horizontal accuracy
X - 198
Selection of the page in the "Display" menu
2 to 30 + Fundamental
3 to 31 + Fundamental
Selection of the page in the "Display" menu
Harmonics
16 + Fundamental
40 to 450 Hz
± 2 % ± +10 D
± 3 % ± +10 D
± 4 %
Triggering search by sample analysis;
Trigger if Detection of:
Trigger if the condition is verified during a parameterizable period:
Oscilloscope equipped with the
EXTENDED ACQUISITION MEMORY option
from 2 seconds to 1 month
From 40µs to 53.5 secs
100 faults in memory up to
200 faults in files
•
Signal above threshold
•
Signal below threshold
•
Signal below or above threshold
•
Signal outside of two defined limits
Recording period / 12500
Recording period / 4
Search for minimum and maximum
Fault search
Identical specifications to those in "Oscilloscope" mode
Technical Specifications
SCOPIX Oscilloscopes