Structure of the Set_Slave_Add Telegram
The net data are stored as follows in the SSA buffer:
Byte
0
1
2
3
4
:
243
Figure 6-4: Structure of the Set_Slave_Add Telegram
6.2.2

Set _Prm (SAP 61)

Parameter Data Structure
The
User_Prm_Data), or the first eight data bytes (with User_Prm_Data). The
first seven bytes are specified according to the standard. The eighth byte is
used for VPC3+S specific characteristics. The additional bytes are available
to the application.
If a PROFIBUS DP extension shall be used, the bytes 7-9 are called
DPV1_Status and must be coded as described in section 7,
"PROFIBUS DP Extensions". Generally it is recommended to start the
User_Prm_Data first with byte 10.
VPC3+S User Manual
Copyright © profichip GmbH, 2012