Functional Principle, Technical Data
3.3
Technical Data
Model
Measurement range
Start of range
Midrange
End of range
Linearity
Resolution
Measurement rate, programmable:
Light source
Laser class
Spot diameter
Protection class
Vibration
Shock
Weight, without cable
Temperature stability
Operation temperature
Storage temperature
Measurement value
output
optoNCDT 1402
ILD 1402-5
1402-10
mm
5
10
mm
20
20
mm
22.5
25
mm
25
30
µm
5 ... 9
5 ... 18
0.6
1
static, µm
1 ... 3
2 ... 5
dynamic, µm
1.5 kHz
SMR, µm
110
110
MR, µm
380
650
EMR, µm
650
1200
0.03 % FSO/°C
analog
digital
1402-20
1402-50
1402-100
20
50
100
30
45
50
40
70
100
50
95
150
7 ... 36
12 ... 90
20 ...180
0.18 % FSO
2
5
10
0.01 % FSO
1
5 ... 10
6 ... 25
12 ... 50
0.02 ... 0.05 % FSO
1.5 kHz; 1 kHz; 750 Hz; 375 Hz; 50 Hz
Semiconductor laser 1 mW, 670 nm (red)
Class 2 (II) acc. to DIN EN 60825-1: 2007
210
1100
1400
530
110
130
830
1100
1400
IP 67
15 g / 10 Hz ... 1 kHz
15 g / 6 ms (IEC 68-2-29)
approx. 83 g
0 ... 50 °C
-20 °C ... 70 °C
4 ... 20 mA (1 ... 5 V with cable PC 1402-3/U) or
RS422
1402-200
1402-250VT
200
250
60
100
160
225
260
350
40 ... 360
50 ... 1200
120 ... 3000
0.5 % FSO
20
50
0.02 % FSO
13 ... 100
32 ... 300
0.02 ... 0.12 % FSO
2300
5000
2200
5000
2100
5000
20 g / 10 Hz ... 1 kHz
approx. 130 g
0.08 % FSO/°C
1402-600
600
200
500
800
120
1
80 ... 600
2,6 x 5 mm
2,6 x 5 mm
2,6 x 5 mm
Page 14
Need help?
Do you have a question about the ILD1402-5 and is the answer not in the manual?