Operation
6.2.2
Pin 9
LED
Error
Fig. 11:
The scaling is also available via the software tool.
Pin 9
LED
Error
Fig. 12:
optoNCDT 1402
Output Scaling via the Hardware Input
Measuring
Start
teaching
Green, red, yellow,
red
depends on
measuring position
t 0
5 min
t 1
2 s
t 2
Timing for the output scaling
Measuring
Green, red, yellow,
red
depends on
measuring position
t 0
5 min
t 1
2 s
Timing for the reset of the output scaling
Position the
Teach-in 1
Positon the
measuring object
measuring
to 4 mA
object to 20 mA
min.
min.
1 ms
30 ms
flashes red
yellow
flashes green
approx. 2 Hz
approx. 2 Hz
t 3
30 s
t 4 t 5
2 s
t 6
flashes red approx. 2 Hz
t 2
5 s
Teach-in 2 Measuring
min.
30 ms
yellow
Color according
to measuring
position
30 s
t 7 t 8
2 s
t 9
Measuring
yellow
Color according
to measuring
position
200 ms
t 5 - t 3 = 2 s
t 3 t 4
t 5
Page 25