Typical Installation, With Circulation - Graco 259079 Operation Manuals

Reactor e-30i series; reactor e-xp2i series; electric, heated, integrated plural component proportioning system with integrated generator
Table of Contents

Advertisement

Typical Installation, with circulation

M
K
G
S
Figure 1
* Shown exposed for clarity. Wrap with tape during operation.
A
Reactor Proportioner
B
Heated Hose
C
Fluid Temperature Sensor (FTS)
D
Heated Whip Hose
E
Fusion Spray Gun
F
Gun Air Supply Hose
G
Feed Pump Air Supply Lines
H
Agitator Air Supply Line
3A1705E
K
H
G
J
R
D
E
P
C*
Typical Installation, with circulation
M
L
J
Fluid Supply Lines
K
Feed Pumps
L
Agitator
M
Desiccant Dryer
P
Gun Fluid Manifold (part of gun)
R
Recirculation Lines
S
Remote Display Module (optional)
R
J
A
F
B
13