Error
Error
Type
Code
Location
A4CM MCM
ALARM
A4DA
Boost A
ALARM
A4DB
Boost B
A4DH
Hose
A4NM MCM
ALARM
A7CH
Hose
ALARM
Boost A
A7DA
ALARM
A7DB
Boost B
A7DH
Hose
A8DA
Boost A
ALARM
A8DB
Boost B
A8DH
Hose
3A1705E
Name
Cause
High MCM
MCM is drawing too
Current
much current from the
system.
High Heater
Short circuit in booster
Current
heater wiring.
Bad heater.
Short circuit in hose
wiring.
High Motor
Short circuit of motor
Current
wiring.
Motor will not rotate.
Chemical pump is stuck
Unexpected
Shorted Temperature
Relay Current
Control Module.
Unexpected
Shorted Temperature
Heater Current
Control Module.
No Heater
Tripped circuit breaker.
Current
Loose/broken
connection.
Troubleshooting
Solution
If problem continues
replace MCM. See System
Repair manual.
Check wiring for touching
wires.
Measure resistance of
heater(s), replace if
needed.
Check continuity of
transformer windings,
normal reading are about
0.2Ω on both primary and
secondary. If reading is 0Ω
replace transformer.
Check for shorts between
the primary winding and
the support frame of the
transformer.
Check wiring to the motor
to ensure no bare wires are
touching and that no wires
are shorted to ground.
Replace motor. See
System Repair manual.
Repair or replace chemical
pump. See System Repair
manual.
Replace Module. See
System Repair manual.
Replace Module. See
System Repair manual.
Visually check circuit
breaker for a tripped
condition.
Check heater wiring for
loose wires.
75