Troubleshooting
Error
Error
Type
Code
Location
L1AX
ADM
ALARM
L1BX
MBN0 MCM
ADVI-
SORY
MMU-
USB
ADVI-
X
SORY
P4AX
MCM
ALARM
P4BX
P6AX
MCM
ALARM
P6BX
78
Name
Cause
Low Chemical
Tanks low on material.
Level A
Low Chemical
Level B
Motor Brush
Brushes have worn
Wear
down and need
replacing.
USB Log Full
USB logs have reached
a level were data loss
will occur if logs are not
downloaded.
Over Pressure A
System pressurized
before allowing heat to
reach setpoint.
Over Pressure B
Bad pressure
transducer.
E-XP2i system
configured as E-30i.
Loose/bad connection.
Pressure
Transducer Fault
A
Pressure
Bad sensor.
Transducer Fault
B
Solution
Fill tanks with material.
Replace Brushes. See
System Repair manual.
Use a USB drive and
download all logs.
Turn on the heat and allow
the hose to reach the
setpoint before turning on
the pumps.
Verify the ADM pressure
reading the analog gauges
at the manifold. Replace
transducers if they do not
match.
Ensure rotary switch on
MCM is set to position 0 for
E-30i.
Check to ensure the
pressure transducer is
properly installed and
all wires are properly
connected.
See if the error follows the
transducer. Disconnect
transducer cable from
#8 and #9 connectors
on MCM. Reverse A
and B connections and
check if the error follows.
If the error follows the
transducer, replace the
pressure transducer. See
system repair manual. If
the error does not follow,
replace MCM. See system
repair manual.
3A1705E