Jog Mode
Circulation Through Gun Manifold
NOTICE
Do not circulate fluid containing a blowing agent
without consulting with your material supplier
regarding fluid temperature limits.
Circulating fluid through the gun manifold allows
rapid preheating of the hose.
1. Install gun fluid manifold (P) on accessory
circulation kit (CK). Connect high pressure
circulation lines (R) to circulation manifold.
P
The Fusion AP gun manifold is shown.
CK
Gun
246362
Fusion AP
256566
Fusion CS
GC1703
Probler P2
2. Route circulation lines back to respective
component A or B supply drum. Use
hoses rated at the maximum working
pressure of this equipment. See
Technical Specifications, page 98.
60
CK
R
Manual
309818
313058
313213
3. Follow procedures from Startup, page 55.
4. Turn main power switch on
5. Set temperature targets. See Targets, page 50.
6. Press
to circulate fluid in jog mode until
A and B temperatures reach targets. See
Jog Mode, page 60 for more information about
jog mode.
Jog Mode
Jog mode has two purposes:
• It can speed fluid heating during circulation.
• It can ease system flushing and priming.
1. Turn main power switch on
2. Press circulate
3. Press up or down
(J1 through J20).
Note
Jog speeds correlate to 3-30% of motor
power, but will not operate over 700 psi
(4.9 MPa, 49 bar) for either A or B.
4. Press
to start motor.
5.
To stop the motor and exit jog mode press
or
.
.
.
to enter jog mode.
to change jog speed
3A1705E