Reactor e-30i series; reactor e-xp2i series; electric, heated, integrated plural component proportioning system with integrated generator
Table of Contents

Advertisement

Error
Error
Type
Code
Location
DADX MCM
ALARM
DE0X
MCM
ALARM
F9DX
MCM
ALARM
H1
Hose
ALARM
MH
H4
Hose
ALARM
MH
K8NM MCM
ALARM
3A1705E
Name
Cause
Pump Runaway
Flow rate is too large
Pump Cycle
Faulty or missing cycle
Switch Fault
switch.
Pressure Flow
Mix chamber is too large
Cutback
for the set pressure.
Low Line
Line frequency is below
Frequency
55 Hz.
High Line
Line frequency is above
Frequency
65 Hz.
Locked Rotor
Locked rotor.
Chemical pump is stuck. Repair or replace pump.
Troubleshooting
Solution
Mix chamber too large for
system selected, use mix
chamber rated for system.
Make sure the system
has chemical and the
feed pumps are operating
correctly.
No material in pumps.
Verify pumps are supplying
chemical. If necessary,
replace or refill drums.
Inlet ball valves are closed.
Open ball valves.
Check wiring between
cycle switch and MCM port
6.
Reference the pressure
flow curves and select a tip
size that is the correct size
for the set pressure.
Check frequency. If
out of tolerance, see
supplied 120/240V
alternator manual for
repair instructions.
Check frequency. If
out of tolerance, see
supplied 120/240V
alternator manual for
repair instructions.
Replace motor. See
System Repair manual.
See System Repair
manual.