Graco 259079 Operation Manuals page 57

Reactor e-30i series; reactor e-xp2i series; electric, heated, integrated plural component proportioning system with integrated generator
Table of Contents

Advertisement

f.
Open fluid inlet valves (FV). Check for leaks.
Do not mix components A and B during
startup. Always provide two grounded
waste containers to keep component A
and component B fluids separate.
g. Hold gun fluid manifold over two grounded
waste containers. Open fluid valves A and B
until clean, air-free fluid comes from valves.
Close valves.
The Fusion AP gun manifold is shown.
14. Setup ADM. Advanced Display Module (ADM)
Operation, page 43.
15. Press
to turn on hose heat zone.
3A1705E
This equipment is used with heated fluid which
can cause equipment surfaces to become very
hot. To avoid severe burns:
• Do not touch hot fluid or equipment.
• Do not turn on hose heat without fluid in
hoses.
• Allow equipment to cool completely before
touching it.
• Wear gloves if fluid temperature exceeds
110°F (43°C).
Thermal expansion can cause
overpressurization, resulting in equipment
rupture and serious injury, including fluid
injection. Do not pressurize system when
preheating hose.
16. Wait for the engine to reach operating
temperature and the hose to reach setpoint
temperature. The engine has reached operating
temperature when the black arrow is under the
green area of the temperature bar. The radiator
fan will turn on when operating temperature is
reached.
17. Wait for the hose to reach set point temperature
or a hose overpressure condition may occur due
to thermal expansion.
18. Press
to turn on A and B heat zones.
Startup