E-30i Series
Part
Available
Includes:
Auxiliary
Booster
Current at
Heat
240 V, 60
(4000
Hz*
Watts)
259079
50 Amps
259080
32 Amps
259089 
30 Amps
259090 
12 Amps
E-XP2i Series
Part
Available
Includes:
Auxiliary
Booster
Current at
Heat
240 V, 60
(4000
Hz*
Watts)
259081
32 Amps
259091 
12 Amps
Total system watts used by system, based on maximum heated hose length of 310 ft (94.5 m) for
each unit.
*
Full load amps available for auxiliary equipment when all bare-system components are operating
at maximum capabilities. Available auxiliary current is based on 310 ft (94.5 m) of heated hose.
An additional 3.0 amps of auxiliary current is available for each 50 ft (15.2 m) section of heated
hose that is not used.
Available auxiliary current will be less when the engine is de-rated for site altitude. Reduce the
Available Auxiliary Current in the chart by 2.5 Amps per 1000 ft (300 m) elevation increments. If the
available auxiliary current is less than zero, the system configuration may not support the full load
at that altitude.
Includes Complete Air Compressor Kit 24K335.
Refer to Circuit Breaker Configuration Options, page 29.
See Approvals, page 10.
3A1705E
Voltage
(phase)
Air
Compressor
(5000 Watts)
240 V (1)
240 V (1)
240 V (1)
240 V (1)
Voltage
(phase)
Air
Compressor
(5000 Watts)
240 V (1)
240 V (1)
Proportioner Models
Total
Max Flow
System
Rate lb/min
Load †
(kg/min)
(Watts)
7,700
30 (13.5)
11,700
30 (13.5)
7,700
30 (13.5)
16,700
30 (13.5)
Total
Max Flow
Approxi-
System
Rate gpm
mate Output
Load †
(lpm)
per Cycle
(Watts)
(A+B) gal.
(liter)
0.0203
11,700
2.0 (7.6)
(0.0771)
0.0203
16,700
2.0 (7.6)
(0.0771)
Approxi-
Maximum
mate Out-
Fluid
put per Cy-
Working
cle (A+B)
Pressure
gal. (liter)
psi (MPa,
bar)
0.0272
2000 (14,
(0.1034)
140)
0.0272
2000 (14,
(0.1034)
140)
0.0272
2000 (14,
(0.1034)
140)
0.0272
2000 (14,
(0.1034)
140)
Maximum
Fluid
Working
Pressure psi
(MPa, bar)
3500 (24.1,
241)
3500 (24.1,
241)
9

Advertisement