Reactor e-30i series; reactor e-xp2i series; electric, heated, integrated plural component proportioning system with integrated generator
Table of Contents

Advertisement

Error
Error
Type
Code
Position
P7AX
MCM
ALARM
P7BX
P0AX
MCM
ADVISORY Pressure
P0BX
MCM
ADVISORY Pressure
T1DE
Heat
ALARM
Exchanger
3A1705E
Name
Cause
Pressure
Pressure difference
Imbalance A High
between A and B material
is greater than the
defined value.
Pressure imbalance is
defined too low.
Out of material.
Feed system defective.
Pressure
Imbalance B High
See P7AX.
Imbalance A High
See P7BX.
Imbalance B High
Low Temperature
Radiator fan will not stop. Replace fan relay.
Coolant Outlet
Engine thermostat is
stuck closed.
Troubleshooting
Solution
Ensure the material flow is
equally restricted on both
material lines.
Ensure that the pressure
imbalance value, on the
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Fill tanks with material.
Check feed pump and hoses
for blockage. Check that the
feed pumps have the correct
air pressure.
Replace thermostat. See
Perkins distribution.