Error Codes and Troubleshooting

See Reactor repair manual for non-error based
troubleshooting.
Error
Error
Type
Code
Location
A1N1
MCM
ALARM
A4CH
Hose
ALARM
74
See Troubleshooting, page 53 for the ten most
recent errors that have occurred on the system. See
Troubleshoot Errors, page 73 to diagnose errors that
have occurred on the system.
See Error Codes and Troubleshooting for error
codes, possible causes, and solutions.
Name
Cause
No Motor Current
Loose or bad
connection.
Motor brushes
completely worn down.
Bad MCM.
High Relay
Wiring problem.
Current Hose
Shorted contactor.
Note
Error codes are stored in the error log and
displayed on the Error and Troubleshooting
screens on the ADM.
Solution
Check wiring between
MCM and motor.
Check motor brushes and
replace if needed.
Replace MCM. See
System Repair manual.
Check wiring between
HPTCM and contactor.
Look for shorted wire
between HPTCM and
contactor terminals A1 and
A2.
Measure resistance
between A1 and A2
terminals. The resistance
should be about 289Ω.
If contactor is measuring
less than 100Ω, then the
contactor is shorted and
should be replaced.
3A1705E