Errors; View Errors - Graco 259079 Operation Manuals

Reactor e-30i series; reactor e-xp2i series; electric, heated, integrated plural component proportioning system with integrated generator
Table of Contents

Advertisement

Errors

Errors

View Errors

When an error occurs the error information
screen displays the active error code and
description. To diagnose the active error, see
Troubleshoot Errors, page 73.
The error code, alarm bell, and active errors will scroll
in the status bar. For a list of the ten most recent
errors see Troubleshooting, page 53.
There are three types of errors that can occur. Errors
are indicated on the display as well as by the light
tower (optional).
Alarms are indicated by
. This condition indicates
a parameter critical to the process has reached a
level requiring the system to stop. The alarm needs
to be addressed immediately.
Deviations are indicated by
. This condition
indicates a parameter critical to the process has
reached a level requiring attention, but not sufficient
enough to stop the system at this time.
Advisories are indicated by
. This condition
indicates a parameter that is not immediately critical
to the process. The advisory needs attention to
prevent more serious issues in the future.
72