Troubleshooting
Error
Error
Type
Code
Position
T4DH
Hose
ALARM
T4DE
Heat
ALARM
Exchanger
T4NM
MCM
ALARM
82
Name
Cause
High Chemical
Bad High Power
Temperature
Temperature Control
Module.
High Temperature
Broken Fan.
Coolant Outlet
Plugged radiator.
High Motor
Cooling fans are not
Temperature
operating properly.
Bad electric motor.
Solution
Replace HPTCM. See
System Repair manual.
Check fan relay (K4) and
fuse (30 Amp ATO "F3") on
load center board. Replace
if needed.
Replace if needed.
Ensure ambient temperature
is less than 120°F(48°C).
Check to see that the fans
are moving. Measure
voltage to fans. There
should be 240 VAC. If no
voltage is measured, check
wiring between fan and
circuit breaker CB03.
If the fans have voltage but
are not moving, replace fan.
Use an air hose to blow out
around the fan housings and
remove any built-up debris.
Replace electric motor. See
System Repair manual.