Troubleshooting
Error
Error
Type
Code
Position
T8DA
Boost A
ALARM
T8DB
Boost B
T8DH
Hose
V1CM MCM
ALARM
V1MH Hose
ALARM
V4CM MCM
ALARM
V4MH Hose
ALARM
WBNM MCM
ALARM
84
Name
Cause
Temperature Not
Bad heater rod (boost).
Rising
Bad hose heater.
Started spraying before
engine and hose reached
operating temperature.
Bus Under
Tripped circuit breaker.
Voltage
Low Line Voltage
Loose or bad connection. Check wiring for loose wires.
Low generator line
voltage
High auxiliary inrush
current.
Bus Overvoltage
Incoming line voltage is
too high.
High Line Voltage
Motor Sensor
Bad Connection between
Fault
MCM (Port 10) and brush
wear/over temperature
board.
Bad brush wear/over
temperature board.
Solution
Measure resistance, 23 – 26
Ω, of heater rod, replace if
reading open.
Measure hose resistance,
replace if reading open.
Wait until temperatures have
been reached on engine and
hose before spraying.
Visually check circuit
breaker for a tripped
condition.
Measure voltage across
main power switch (CT01).
Voltage should measure
between 190 and 264 VAC.
Ensure compressor or
air drier are setup to be
continuous run and sized
according to manual.
Measure voltage across
main power switch (CT01).
Voltage should measure
between 190 and 264 VAC.
If voltage is too high, see
supplied alternator manual
for generator specifications
and repair.
Check connection and
cables.
Replace Motor. See System
Repair manual.
3A1705E