Temporary Manual Hose Temperature Control

Temporary Manual Hose
Temperature Control
If T6DH error code appears from a break in the
hose RTD cable or FTS sensor, follow the steps for
temporary manual hose temperature control. Repair
or replace the hose RTD cable or FTS as soon as
job is finished.
1. Connect the spare RTD (15V837), shipped with
the system, to the Fluid Temperature Sensor
(FTS) cables (SC) at the Reactor Fluid Manifold
(FM).
A
SC
15V837
58
2. Insert the RTD sensor probe between the two
hoses where the scuff guard ends.
3. Lower the hose temperature setpoint on the
system ADM screen by (20°F (-6°C). Push probe
into the hose bundle at least 3 in. (76 mm).
4. Do not leave the RTD tip probe exposed to air or
a hose overtemperature condition may occur.
To prevent overheating material and damaging
the hoses, do not leave the spare RTD between
the two hoses after the job is complete.
5. Repair or replace the hose RTD cable or FTS as
soon as the job is finished.