18.2
Step 1) Surveying the Points
Description
Surveying points
246
•
To measure points to a new surface or to an existing surface in the active job. If
no surfaces currently exist in the active job, the user has to enter a New Surface
first in VOLUMES Choose Task & Surface. The menu items Triangulate
Surface and Compute Volume within the VOLUMES Volumes & Surfaces
Menu are marked grey if no surface exists in the active job.
•
This menu lists all of the necessary steps and the option to close the program.
TPS1200+/TS30/TM30
ALL (F1)
To measure and store distances and
angles.
STOP (F1)
Available if <EDM Mode: Tracking>
and DIST (F2) was pressed. Stops
the distance measurements. (F1)
changes back to ALL.
DIST (F2)
To measure and display distances.
Available unless <EDM Mode:
Tracking> and/or <Log Auto Pts:
Yes>, after the tracking or logging is
started.
REC (F3)
To record data.
If <EDM Mode: Tracking> and/or
<Log Auto Pts: Yes>, records
measured point and continues
tracking.
>BNDY (F3) / >SURF (F3)
To change the class of the point to be
measured between surface point and
boundary point.
DONE (F5)
To finish measuring and to return to
the Volumes Calculations Menu.
PAGE (F6)
To change to another page on this
screen.
SHIFT INDIV (F5) and SHIFT RUN (F5)
To change between entering an indi-
vidual point ID different to the defined
ID template and the running point ID
according to the ID template.
Volume Calculations