4

Determine Coordinate System - Normal

4.1

Determining a New/Updating a Coordinate System

Access
step-by-step
DET C SYS
Step 1: Choose
Transform Type
Determine Coordinate System - Nor-
mal
Step
Description
1.
PROG. The PROG key opens the TPS1200+/TS30/TM30 Programs
menu.
2.
Select Determine Coordinate System and press CONT (F1).
3.
Press CONF (F2) to access DET C SYS Configuration.
Select <Default Method: Normal>.
If a coordinate system was chosen to be edited in DET C SYS Determine Coord
System Begin, pressing CONT (F1)
(n).
Description of fields
Field
<Transfrm Name:> User input
<Transfrm Type:> Onestep,
<Height Mode:>
Next step
CONT (F1) continues to DET C SYS Step 2: Choose Parameters.
TPS1200+/TS30/TM30
accesses
Option
Description
A unique name for the transformation. If a
coordinate system is being updated then
its name is displayed.
Available when determining a new coordi-
Twostep or
nate system.
Classic 3D
Output
Available when updating a coordinate
system. The transformation type shown is
the same as the transformation used in
the existing system.
Orthometric or
Available when determining a new coordi-
Ellipsoidal
nate system.
Output
Available when updating a coordinate
system. The height mode shown is the
same as the mode used in the existing
system.
DET C SYS Step 3: Match Points
55