Mounting Environment
Set the Motion controller system according to the mounting environment indicated in the general specifications.
Do not install the Motion controller system in the following environments.
• Where ambient temperature exceeds the range of 0 to 55[] (32 to 131[]).
• Where ambient humidity exceeds the range of 5 to 95[%]RH.
• Where condensing from sudden temperature changes occurs.
• Where there is corrosive or inflammable gas.
• Where there is a lot of conductible dust, iron filings, oil mist, or salt, organic solvents.
• Where there is direct exposure to sunlight.
• Where there is strong electrical or magnetic fields.
• Where there are direct vibrations or shocks to the Motion controller.
*1 When an extended temperature range base unit is used, each module can be used in the environment of 0 to 60[] (32 to 140[]).
3.2
Module Installation
Mounting position
When mounting the Motion controller to an enclosure or similar, fully consider its operability, maintainability and environmental
resistance.
Refer to the following for details of mounting position of modules.
MELSEC iQ-R Module Configuration Manual
Installation of the base unit
Refer to the following for details of installation of base unit to control panel and installation of base unit to DIN rail.
MELSEC iQ-R Module Configuration Manual
Installation and removal of module
Refer to the following for details of how to install and remove a power supply module, PLC CPU module, Motion CPU module,
I/O module, intelligent function module or another module to and from the base unit, and installation precautions.
MELSEC iQ-R Module Configuration Manual
3 INSTALLATION AND WIRING
50
3.1 Mounting Environment
*1