Pump-To-Driver Alignment Instructions - Goulds Pumps 3700 Installation, Operation And Maintenance Manual

Api type oh2 / iso 13709 1st and 2nd ed. / api 610 8/9/10/11th ed.
Table of Contents

Advertisement

Installation
b) Attach the other indicator (A) so that the indicator rod comes into contact with the inner
Figure 13: Dial indicator attachment
2. Rotate the pump coupling half (X) in order to check that the indicators are in contact with
the driver coupling half (Y) but do not bottom out.
3. Adjust the indicators if necessary.

Pump-to-driver alignment instructions

Perform angular alignment for a vertical correction
1. Set the angular alignment indicator to zero at the top-center position (12 o'clock) of the
driver coupling half (Y).
2. Rotate the indicator to the bottom-center position (6 o'clock).
3. Record the indicator reading.
When the
reading value
is...
Negative
Positive
1. Shims
Figure 14: Example of incorrect vertical alignment (side view)
4. Repeat the previous steps until the permitted reading value is achieved.
26
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
end of the driver coupling half.
This indicator is used to measure angular misalignment.
Then...
The coupling halves are farther apart at the bottom than at the top. Perform one of
these steps:
• Add shims in order to raise the feet of the driver at the shaft end.
• Remove shims in order to lower the feet of the driver at the other end.
The coupling halves are closer at the bottom than at the top. Perform one of these
steps:
• Remove shims in order to lower the feet of the driver at the shaft end.
• Add shims in order to raise the feet of the driver at the other end.