Installation

Auxiliary-piping checklist

Precautions
WARNING:
must be operating properly to prevent excess heat generation, sparks, and premature
failure.
manual venting prior to operation. Failure to do so will result in excess heat generation and
seal failure.
NOTICE:
The mechanical seal must have an appropriate seal-flush system. Failure to do so will
result in excess heat generation and seal failure.
When to install
You may need to install auxiliary piping for bearing cooling, seal-chamber cover cooling,
mechanical seal flush, or other special features supplied with the pump. Consult the pump data
sheet for specific auxiliary piping recommendations.
Checklist
Check
Check that the minimum flow for each
component is 4 lpm | 1 gpm.
If the bearing and seal chamber cover
cooling are provided, then the auxiliary
piping must flow at 8 lpm | 2 gpm.
Check that the cooling water pressure
does not exceed 7.0 kg/cm

Final piping checklist

Check
Check that the shaft rotates smoothly. Rotate the shaft by hand. Make sure there is no
Re-check the alignment to make sure
that pipe strain has not caused any
misalignment.
36
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
Cooling systems such as those for bearing lubrication and mechanical-seal systems
Sealing systems that are not self-purging or self-venting, such as plan 23, require
2
| 100 psig .
Explanation/comment
Make sure that these guidelines are followed.
Make sure that these guidelines are followed.
Explanation/comment
rubbing that can lead to excess heat generation or
sparks.
If pipe strain exists, then correct the piping.
Checked
Checked
Manual