Preassembly inspections

Replacement guidelines

Casing check and replacement
WARNING:
Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Inspect and ensure
gasket sealing surfaces are not damaged and repair or replace as necessary.
Inspect the casing for cracks and excessive wear or pitting. Thoroughly clean gasket surfaces
and alignment fits in order to remove rust and debris.
Repair or replace the casing if you notice any of these conditions:
• Localized wear or grooving that is greater than 3.2 mm | 1/8 in. deep
• Pitting that is greater than 3.2 mm | 1/8 in. deep
• Irregularities in the casing-gasket seat surface
Casing areas to inspect
The arrows point to the areas to inspect for wear on the casing:
100
164
Figure 51: Areas to inspect for wear on casing
Impeller replacement
This table shows the criteria for replacing the impeller:
Impeller parts
Impeller vanes
Pumpout vanes
Vane edges
Impeller checks
NOTICE:
Protect machined surfaces while cleaning the parts. Failure to do so may result in equipment
damage.
• Check and clean the impeller bore diameter.
• Check the impeller balance. Rebalance the impeller if it exceeds the ISO 1940 G1.0
criteria.
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
Manual
Casing
Casing wear ring
When to replace
• When grooved deeper than 1.6 mm | 1/16 in.,
or
• When worn evenly more than 0.8 mm | 1/32 in.
When worn or bent more than 0.8 mm | 1/32 in.
When you see cracks, pitting, or corrosion damage