Maintenance
Check
Shaft impeller fit
Shaft seal fit
96
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
Procedure
1. Mount the dial indicator on the bearing frame.
2. Rotate the shaft through a maximum arc from one side of the keyway to the
other. If the total indicator reading is greater than 0.050 mm | 0.002 in.,
determine the cause and correct it.
1. Mount the dial indicator.
2. Rotate the shaft so that the indicator rides along the shaft surface for 360°. If
the total indicator reading is greater than 0.050 mm | 0.002 in., then
determine the cause and correct it.