Check
Bearing-frame
face
Bearing-frame
lock
10. Install and tighten any plugs and fittings removed during disassembly, including the oil-
drain plug, and the sight glass.
11. If your power end has the optional water cooling package, install the finned-tube cooling
assembly into the bearing frame.
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
Manual
Procedure
1. Mount the dial indicator on the shaft.
2. Rotate the shaft so that the indicator rides along the bearing-frame face for
360°. If the total indicator reading is greater than 0.10 mm | 0.004 in., then
disassemble and determine the cause and correct it.
1. Mount the dial indicator on the shaft.
2. Rotate the shaft so that the indicator rides along the bearing-frame lock for
360°. If the total indicator reading is greater than 0.10 mm | 0.004 in., then
disassemble and determine the cause and correct it.