Alarm, Error And System Messages - Siemens SIMATIC IPC277D Operating Instructions Manual

Industrial pc
Hide thumbs Also See for SIMATIC IPC277D:
Table of Contents

Advertisement

Technical specifications
9.6 BIOS description
9.6.5

Alarm, error and system messages

During startup (the boot process), the BIOS first performs a Power On Self Test (POST) and
checks whether certain functional units of the PC are operating error-free. The boot
sequence is immediately interrupted if critical errors occur.
BIOS initializes and tests further functional units if the POST does not return any errors. In
this startup phase, the graphics controller is initialized and any error messages are output to
the screen.
The error messages output by system BIOS are listed below. For information on error
messages output by the operating system or application programs, refer to the
corresponding manuals.
On-screen error messages
On-screen error message
Operating system not found
Keyboard controller error
SMART error
Real-time clock error
Real-time clock has lost power
CMOS battery error
CMOS battery failed
156
Meaning/tip
Possible causes:
No operating system installed
Operating system available, but the partition is not active
Controller error.
Contact your technical support team.
Hard disk reports pending failure through S.M.A.R.T.
Battery is weak
Time corrupt due to discharged battery
Battery exhausted
Battery empty or not inserted