Installing and connecting the device
3.2 Installing the device
Requirement
● All packaging components and protective foils should be removed from the HMI device.
● To install the HMI device, you need the mounting clamps from the accessory kit.
Procedure
Result
The HMI device is mounted and the relevant degree of protection is ensured at the front.
40
Insert the HMI device into the
mounting cutout from the front.
Insert a mounting clamp into the
cutout provided on the HMI de-
vice.
Tighten the mounting clamp with
the threaded pin. The threaded
pins of the mounting clamps have
a maximum tightening torque of
0.5 Nm on the 7, 9, and 12 inch
variants.
Repeat steps 2 and 3 for all
mounting clamps.
Check the fit of the mounting seal.
Operating Instructions, 12/2016, A5E03409486-AE