Siemens SIMATIC Rack PC IL 40 Getting Started

Siemens SIMATIC Rack PC IL 40 Getting Started

Intel pentium 4 platform, first steps in commissioning

Advertisement

Quick Links

SIMATIC
Rack PC IL 40
Intel Pentium 4 Platform
Getting Started
First Steps in Commissioning
Edition 03/2003
A5E00171493-02
Contents, Preface
Important Information
Commissioning
Operating
Appendix
Guidelines for ESD
1
2
3
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC Rack PC IL 40

  • Page 1 Contents, Preface Important Information SIMATIC Commissioning Operating Rack PC IL 40 Intel Pentium 4 Platform Appendix Guidelines for ESD Getting Started First Steps in Commissioning Edition 03/2003 A5E00171493-02...
  • Page 2: Important Information

    Trademarks SIMATIC®, SIMATIC HMI® and SIMATIC NET® are registered trademarks of SIEMENS AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners.
  • Page 3: Table Of Contents

    Access protection under Windows ..............3-7 3.10.3 BIOS Setup security functions ................3-7 Guidelines for Handling Electrostatically-Sensitive Devices (ESD)......A-1 What is ESD? ....................A-1 Electrostatic Charging of Persons..............A-2 General Protective Measures Against Electrostatic Discharge Damage..A-3 SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 4 Contents SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 5: Preface

    Canadian Standard Association (CSA) to Standard C22.2 No. 950 Standards and Approvals The device fulfils the requirements for the CE approval. Further information on the approvals, certificates, and licenses for your device is provided in Chapter 1. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 6 The manual offers information on useful topics, for example, optional hardware- expansion and technical data. Further Support If you have any technical questions, please get in touch with your Siemens representative or agent responsible. http://www.siemens.com/automation/partner Training Centers Siemens offers a number of training courses to familiarize you with the SIMATIC S7 automation system.
  • Page 7 +49 (0) 180 5050-223 E-Mail: simatic.hotline@ E-Mail: adsupport.asia@ E-Mail: adsupport@ siemens.com sea.siemens.com siemens.com GMT: +1:00 GMT: -5:00 GMT: +8:00 The languages of the SIMATIC Hotlines and the authorization hotline are generally German and English. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 8 A forum, where users and experts from all over the world exchange their experiences. • Your local representative for Automation & Drives via our representatives database. • Information on field service, repairs, spare parts and more under "Services". SIMATIC Rack PC IL 40, Getting Started viii A5E00171493-02...
  • Page 9: Important Information

    Take note of the permissible fitting positions without fail when installing the systems (see Section 2.2). If the systems are installed in a non-permissible fitting position, the approvals pursuant to UL 1950 and EN60950 are no longer valid! SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 10 To establish a complete power separation, you must disconnect the power plug (inlet connector on the back of the device). This location must be accessible. A central isolating switch must be present for cabinet mounting. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 11 There are fast-running fans in Rack PC IL 40 which may cause injury when touched. Note There is a filter mat behind the front panel, check it regularly for dirt and change it if necessary. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 12 Touch modules fitted with ESDs by their edges only. • Never touch wiring posts or printed conductors on modules containing ESDs. For more information on electronic charging and safety measures, refer to Appendix A. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 13: Certificates, Directives And Declarations

    EC directive, from: Siemens AG Bereich Automation and Drives A&D AS RD 4 Postfach 1963 D-92209 Amberg Tel.: +49 (9621) 80-3283 Fax: +49 (9621) 80-3278 SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 14 Peripherals should only be connected via shielded cables. Software License Agreement The SIMATIC Rack PC IL is shipped with the operating system on the Restore CD. Please observe the relevant license agreements. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 15: Certification For The Usa, Canada And Australia

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 16: Transport

    When transporting the PC in cold weather, when it may be submitted to extreme variations in temperature, make sure that there is no moisture (condensation) on or in the PC. The PC must be allowed to reach room temperature slowly before you switch it SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 17: Commissioning

    8. Enter the Microsoft Windows "Product Key" from the "Certificate of Authenticity" (COA) in the table. The product key is on the back of the device. F-No. Order No. Microsoft Windows Product Key Ethernet Address SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 18: Installing The Simatic Rack Pc Il

    PC out of the cabinet or rack. Notice If the systems are installed without keeping to the conditions mentioned above, the approvals pursuant to UL 1950 and EN60950 are no longer valid! SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 19 Commissioning Dimensioned Drawing for installation in cabinet 19" Upwards for vertical installation 433,6 Upwards for vertical installation SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 20 470 mm Rail thickness maximum 9,7 mm Fixing screws M5 x 6mm The fixing screw of the telescopic rail should not go beyond a maximum of 5 mm into the housing. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 21: Preparing For Operation

    Rack PC IL (see Section 2.6.) 2. Press the On/Off button behind the front door, the PC is in operation. The Power LED lights green. Power LED On/Off button SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 22: Initial Startup

    "Partial Recovery", the data on "D" (Partition DATA) will be retained. Always select "Full Recovery" for the first commissioning. "Partial Recovery" can only be used for reinstallation if the partition name and, if applicable, the partition size are not changed. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 23 Confirm your settings – the system settings are updated now. Then, the date/time dialog is opened. Enter the correct date/time, if necessary, and confirm your settings. Close Windows and restart the Rack PC to fully integrate the upgraded. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 24: Normal Operation

    4. Close the opened window. Bear in mind that the ramp-up time of the computer increases considerably when the DHCP service is activated, however if the Rack IL is not connected to a corresponding network. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 25: Connecting Peripheral Units

    Using a Mouse You can connect a PS/2 mouse as well as a USB mouse to the Rack PC IL. The USB port is only supported by Windows 2000 and Windows XP. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 26 If you want to set higher clock frequencies and resolutions, first make sure that the monitor you are using is suitable for a higher clock frequency and resolution. If the clock frequency is too high, this can cause damage to the monitor. SIMATIC Rack PC IL 40, Getting Started 2-10 A5E00171493-02...
  • Page 27 Legacy Support“ in the BIOS Setup has to be activated. Notice Operating systems which do not support Plug and Play (e.g. WindowsNT) generally do not allow the use of USB devices. SIMATIC Rack PC IL 40, Getting Started 2-11 A5E00171493-02...
  • Page 28: Ethernet (Rj45 Ethernet Port)

    Windows supports point-to-point connections via the LPT or COM port. The required connecting cables are standard, commercially available products. More information is available in the online Help system under "Connection to Another Computer". SIMATIC Rack PC IL 40, Getting Started 2-12 A5E00171493-02...
  • Page 29: Operating

    Placing a PC (with soft power off function) in a ready-to-operate-state by means of software. After quitting the operating system, the PC automatically shuts down using the soft power off function (ready to run). Notice This function is not available under Windows NT. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 30: Operating Modes

    If you press the On/Off button once for more than four seconds, the Rack PC IL will be switched off, without shutting down the operation system (Reset). Briefly pressing the On/Off button again will restart the operating system. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 31: Leds At The Pc

    You will find a comprehensive description of the monitoring functions in the technical manual on system modules on the supplied CD "Rack PC IL 40 Documentation and Drivers". SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 32: Floppy Disk Drive

    4 = Identification of a 1.44 MB floppy disk or write protect switch on a 120 MB floppy disk 5 = Eject button for inserted floppy disks 6 = Disk is write-protected 7 = Disk is not write-protected SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 33 CD, even when no error message is displayed. Correctly written data can only be guaranteed by an additional comparison with the source data. To ensure an error-free copying process do a data comparison after every burning session. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 34: Bios-Settings

    Pay special attention to making the settings in the index Power correctly. All menu items are disabled by default. The operating system's functions "Save to RAM" (standby) and "Save to Disk" (hibernate) are not enabled functions for Rack PC IL. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 35: Property And Data Protection

    You can also combine these functions. You will find a detailed description of the Security menus and how to assign passwords in the technical manual for the system board or in the "BIOS Setup" manual. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 36 Operating SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 37: A Guidelines For Handling Electrostatically-Sensitive Devices (Esd

    In most cases, the damage caused by an overvoltage is not immediately noticeable and results in total damage only after a prolonged period of operation. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 38: Electrostatic Charging Of Persons

    Antistatic material, for example, wood or concrete 5 10 20 30 40 50 60 70 80 90 100 Relative air humidity in % Figure 7-1 Electrostatic Voltages which can Build up on a Person SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 39: General Protective Measures Against Electrostatic Discharge Damage

    If you have to carry out measurements on a module, you must discharge your body's electrostatic charge before you start the measurement by touching grounded metallic parts. Use grounded measuring devices only. SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...
  • Page 40 Guidelines for Handling Electrostatically-Sensitive Devices (ESD) SIMATIC Rack PC IL 40, Getting Started A5E00171493-02...