9.6.3.6

Boot menu

In this menu this booting behavior of the device is specified and the boot medium or
sequence of the boot media is determined.
Entries in the boot menu
Entry
Quick Boot
Quiet Boot
Boot delay
POST errors
Numlock
USB Boot
PXE Boot to LAN 2
SIMATIC IPC277D
Operating Instructions, 12/2016, A5E03409486-AE
Meaning
Enable or disable
If enabled, the device starts faster because various hardware function
tests are skipped.
If disabled, the device boots in text mode. If enabled, a splash screen with
logo is output.
Delays the boot sequence by n seconds.
Specification of the boot reaction when faults are detected.
Never halt on errors: Continue the booting process when errors occur.
Halt on all errors: Interrupt the booting process when errors occur.
All without keyboard: Interrupt the booting process when errors occur,
except for keyboard errors.
All without kb/smart: Interrupt the booting process when errors occur,
except for keyboard and S.M.A.R.T errors. (SMART: Self-Monitoring,
Analysis and Reporting Technology)
On = Enable numeric keypad on right
Off = Disable numeric keypad on right (= navigation)
Allow/Do not allow booting of inserted USB devices.
Enable or disable booting of the LAN2 via PXE.