Chapter 1
Operations When Using Oracle Fibre Channel Cards
1.3
Setting Up the Server
For x86
-
Specify the command queue depth for the "sd_max_throttle" parameter.
Add this parameter if it does not exist.
Example:
set sd:sd_max_throttle = 20
2
After editing the configuration file, save it.
3
After the setting is complete, check the configuration file for incorrect settings.
4
Reboot the server.
# /usr/sbin/shutdown -y -g0 -i6
1.3.2

Oracle Driver for Emulex OEM Fibre Channel Cards

When connecting using an Emulex OEM Fibre Channel card and Oracle Fibre Channel card driver, the configu-
ration file will need to be edited as follows.
The "command queue depth" setting must be adjusted for both direct connection and switch connection. The
"command queue depth" setting is specified in the configuration file (/etc/system).
For direct connection
Instance name data of the Fibre Channel card is necessary. Refer to the following sections to set.
"1.3.2.1 Creating a WWN Instance Management Table for the Server" (page 13)
"1.3.2.2 Setting the Configuration File (emlxs.conf)" (page 16)
"1.3.2.3 Setting the Configuration File (/etc/system)" (page 16)
For switch connection
The Fibre Channel card Instance name, target WWN, and target ID information are necessary. Check each
item and enter them in the table. Edit the configuration file according to those information and make set-
tings. Refer to the following sections to set.
"1.3.2.1 Creating a WWN Instance Management Table for the Server" (page 13)
"1.3.2.2 Setting the Configuration File (emlxs.conf)" (page 16)
"1.3.2.3 Setting the Configuration File (/etc/system)" (page 16)
1.3.2.1
Creating a WWN Instance Management Table for the Server
Create a "WWN instance management table for the server" with information regarding the Fibre Channel card
installed in the server.
For each Fibre Channel card that is installed in the server, check the physical slot names, WWN, instance
names, physical path names, and controller number of the target connected to the Fibre Channel card and
enter them in the "WWN instance management table for the server" (provided in
agement Table Templates" (page
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris