Chapter 1
Operations When Using Oracle Fibre Channel Cards
1.3
Setting Up the Server
4
Check the WWN of each Fibre Channel card.
(1)
Use the following command to check the display order of the Fibre Channel card physical path
names.
# prtpicl -v -c scsi-fcp | grep devfs-path
Example:
# prtpicl -v -c scsi-fcp | grep devfs-path
:devfs-path /pci@9,600000/SUNW,qlc@1
:devfs-path /pci@9,600000/SUNW,qlc@2
(2)
Use the following command to check the WWN of the Fibre Channel card that corresponds to the
physical path name. The result is displayed in the same order as shown in
# prtpicl -v -c scsi-fcp | grep port-wwn
Example:
# prtpicl -v -c scsi-fcp | grep port-wwn
:port-wwn 21 00 00 e0 8b 12 6d 70
:port-wwn 21 00 00 e0 8b 16 cf fd
5
Add the results in the "WWN instance management table for the server".
Example:
Physical slot
name
PCIE 0
PCIE 1
6
Check the controller number of the target connected to the Fibre Channel card.
Use the following command to check the controller number of the target connected to the Fibre Chan-
nel card. The controller number corresponds to the physical path displayed in
# cfgadm -v
Example:
# cfgadm -v
Ap_Id Receptacle Occupant Condition Information
When Type Busy Phys_Id
c4 connected unconfigured unknown
unavailable fc-fabric n /devices/pci@9,600000/SUNW,qlc@1/fp@0,0:fc
c5 connected unconfigured unknown
unavailable fc-fabric n /devices/pci@9,600000/SUNW,qlc@2/fp@0,0:fc
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Controller num-
WWN
ber
210000e08b126d70
210000e08b16cffd
11
Copyright 2017 FUJITSU LIMITED
Step
(1).
Instance name
Physical path name
qlc0
/pci@9,600000/SUNW,qlc@1
qlc1
/pci@9,600000/SUNW,qlc@2
Step
(1).
P3AM-6312-18ENZ0