Page 3
This chapter describes how to check the server's WWN settings. "Chapter 5 Setting Up the ETERNUS AF/DX" (page 15) • This chapter describes how to set up the ETERNUS AF/DX storage systems using ETERNUS Web GUI. "Chapter 6 Setting Up the Fibre Channel Switches" (page 16) •...
Chapter 6 Setting Up the Fibre Channel Switches Chapter 7 Installing Drivers and Setting Up the Server 7.1 Installing the Driver........................18 7.2 Setting Up the Server........................18 FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Workflow Setting Up the ETERNUS AF/DX Set the various parameters required to operate the ETERNUS AF/DX. Also, check the WWN of the Fibre Channel card for the server that is required to set the ETERNUS AF/DX. "Chapter 4 Checking the Server Information" (page 13) •...
Page 7
• Setting Up the Server to Recognize the Logical Units Set up the server so that it can recognize the LUNs (logical unit numbers) of the ETERNUS AF/DX. "8.2 Setting Up the Server to Recognize the Logical Units" (page 21) •...
Refer to the "Server Support Matrix". Integrity VM Refer to the "Server Support Matrix". Veritas Volume Manager (VxVM) Refer to the "Server Support Matrix". FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Chapter 2 Checking the Server Environment Veritas Cluster Server (VCS) Veritas Cluster Server (VCS) Refer to the "Server Support Matrix". FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
The Fibre Channel switches that can be connected depend on the connection configuration that is used (the OS and the ETERNUS AF/DX). Refer to the "Server Support Matrix for FC-SWITCH" before starting. When a Fibre Channel switch (ETERNUS SN200 series, Brocade series) is to be used between the server and ETERNUS AF/DX, follow the preparation-in-advance and Fibre Channel switch setup procedures given in the "Configuration Guide -Server Connection- (Fibre Channel) Fibre Channel Switch Settings".
Example: # lvchange -r N /dev/vg01/lvol_name Execute this command for all logical volumes created on ETERNUS AF/DX storage systems' LUNs to disable [Bad Block Relocation]. If [Bad Block Relocation] is not disabled, file system may be damaged. Raw device access to an LVM logical volume must use an I/O block size that is a multiple of 1024bytes.
"Ready". If the server is turned on and they are not "Ready", the server will not be able to recognize the ETERNUS AF/DX storage systems. Also, when the ETERNUS AF/DX power supply is being controlled by a connected server, make sure that the ETERNUS AF/DX does not shut down before the connected servers. Similarly, the Fibre Channel switches must also be turned off after the connected servers have been shut down.
Check the World Wide Name (WWN). When using the "Security" function (Affinity Mode) of the ETERNUS AF/DX storage systems, it is necessary to specify the WWN of the Fibre Channel card. Use the "fcmsutil" command to specify the device file of the Fibre Channel card, and the WWN of the Fibre Channel card can be checked.
Page 14
The WWNs identified here are needed for the "Add WWN" function of ETERNUS Web GUI. Refer to "ETERNUS Web GUI User's Guide" for details. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED...
Setting Up the ETERNUS AF/DX Set up the ETERNUS AF/DX storage systems using ETERNUS Web GUI. ETERNUS AF/DX setup can be performed independently of server setup. For details on how to perform these settings, refer to the following manuals. •...
Chapter 6 Setting Up the Fibre Channel Switches Perform the settings required to connect the ETERNUS AF/DX storage systems and server via the Fibre Chan- nel switch, according to "Configuration Guide -Server Connection- (Fibre Channel) Fibre Channel Switch Set- tings".
Page 17
Port6 FC switch FC switch Port1 Port3 Port5 Port7 Port1 Port3 Port5 Port7 Cascading Port0 Port1 Port0 Port1 line ETERNUS AF/DX FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
To achieve maximum system performance, this value can be changed according to the server load • and the peak operating times. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 19
LUNs: 10 Affinity Group For connection schemes in which an ETERNUS AF/DX FC port is shared by multiple servers, the command queue depth is again determined by the number of LUNs recognized by each server on the single path. In this example, "51"...
Page 20
Setting the command queue depth of disk20 to 8 # scsimgr save_attr -D /dev/rdisk/disk20 -a max_q_depth=8 Refer to the HP-UX manuals for details of the "scsimgr" command. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Turn on the server. Setting Up the Server to Recognize the Logical Units Make the server recognize the logical units (LUN) set in the ETERNUS AF/DX storage systems. Use the "ioscan" command to check which devices are connected. Enter as follows for LegacyView (old format) results:...
Page 22
FUJITSU ETERNUS_DX400 When the ETERNUS AF/DX storage systems are connected for the first time, the device file (for exam- ple, /dev/dsk/c4t0d0) sometimes may not be created. If this happens, use the "insf" command to create the device file. Specify the hardware path name as follows, and execute.
IDs, by checking the ETERNUS AF/DX CA port settings for each PV-Link path and comparing the target IDs. When set correctly, the device files for all paths that connect to a given ETERNUS AF/DX LUN should all be the same after the "t" part of the name (e.g. "/dev/dsk/c4t0d0" g "0d0").
9.2.1 Setting the I/O Load Balance Policy (load_bal_policy) Set the I/O load balance policy to match the ETERNUS AF/DX model being used as shown below. The policy setting is required for all LUNs in the ETERNUS AF/DX. I/O load balance policy setting vs ETERNUS AF/DX model •...
Set "alua_enabled". Use the "scsimgr" command to set the "alua_enabled" attribute to "true" for each LUN. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 26
Multipath Configuration Using Native Multipath Example for setting "alua_enabled" # scsimgr save_attr -D /dev/rdisk/disk25 -a alua_enabled=true Value of attribute alua_enabled saved successfully FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
• server, OS, or the Fibre Channel card that is to be used. When using a logical unit (LUN) of the ETERNUS AF/DX storage systems as a boot disk, make sure that the • LUN has enough capacity to install the OS.
Chapter 11 Storage Migration This chapter explains how to configure the server for performing Storage Migration. When Storage Migration is performed, configure the settings so that the ETERNUS AF/DX LUNs can be used from the server (HP-UX). ■ Setting Procedure Outline Execute the operation to start Storage Migration from ETERNUS Web GUI.
Page 29
5119 Alloc PE 5000 Free PE Total PVG Total Spare PVs Total Spare PVs in use (Continued on the next page) FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 31
# strings vg01.map 1 lvol1 (Omitted) fCheck the content of the collected files. # strings vg08.map 1 lvol1 Turn off the server. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 32
Allocated PE Used PV --- Physical volumes --- PV Name /dev/dsk/c1t0d0s2 PV Status available Total PE 4228 Free PE Autoswitch Proactive Polling FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 33
For /dev/vg01, the device name of the Primary Link is /dev/dsk/c2t0d0 and the device name of the Alternate Link is /dev/dsk/c4t0d0. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 34
The adapter number for the Primary Link for vg01 is "0/2/0/0/0/0", and the LUN is "0". The adapter number for the Alternate Link for vg01 is "0/4/0/0/0/0", and the LUN is "0". FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED...
Page 35
In some cases, /dev/dsk/c6txdx will not be the Primary Link. Therefore, it is necessary to check each vg and make the appropriate settings. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED...
Page 36
894269 18361628 5% /mnt/file06 After this procedure is completed, the file system can be used in the migration destination ETERNUS AF/DX the same way as before the migration. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX...
Connect the multipath. Add the host affinity setting to the migration destination storage system. Rescan the device. [Thu Aug 03 20:00:51 rx28001:/] ioscan FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 38
CLAIMED LUN_PATH LUN path for disk83 lunpath 0/0/0/31/2.0x0.0x0 eslpt CLAIMED LUN_PATH LUN path for disk7 [Thu Aug 03 20:02:38 rx28001:/] FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 39
[Thu Aug 03 20:08:02 rx28001:/] Although "NO_HW" remains in "State", there is no problem. This is deleted after the server is reboo- ted. FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 40
= 72 Hardware path = 0/0/0/8/0/0/0/5/0/0/0.0x500000e0da120931.0x4004000000000000 SCSI transport protocol = fibre_channel State = STANDBY Last Open or Close state = STANDBY FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 41
= 72 Hardware path = 0/0/0/8/0/0/0/5/0/0/0.0x500000e0da120931.0x4004000000000000 SCSI transport protocol = fibre_channel State = STANDBY Last Open or Close state = STANDBY FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX Copyright 2020 FUJITSU LIMITED P3AM-3772-22ENZ0...
Page 42
• operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information • in this manual.