16. Quick lock configuration

The following tables describe the sequence of commands required to configure the lock from factory,
construction and access mode. Note that:
Typically a timeout of 5 seconds applies to key presses and card detection. After this delay, the
o
current operation is cancelled (red led turns on along with low pitch sound).
Keypad commands are always followed by a '#' key.
o

16.1 In Factory or Construction mode

Step
Sub
1
1
2
3
4
2
1
3
1
2
3
4
1
2
3
4
Description/Operation
Reset the lock to factory mode
Insert and turn mechanical key in key
cylinder to retract latch and hold
Press and release '#' key on lock keypad
Release mechanical key
Enter reset command:
12345678#
o
Enter lock keypad programming.
Enter keypad programming mode by
typing:
#12345678#
o
Change default (factory mode) PIN
Enter the change PIN command:
000#
o
Enter the new (construction mode) PIN:
XXXXXXXX#
o
Enter the new PIN AGAIN:
XXXXXXXX#
o
Prepare the maintenance unit (M-Unit)
Start the E-Plex 5900 M-Unit application
on the PDA
Select 'Comm key' option
Enter the communication key (16 zeros
by default) and select 'ok'
Select the 'Set Time' option and set the
date/time related parameters.
Notes
Note: Resetting the lock to factory defaults
can be done while in any mode -> factory,
construction or access.
Once done, red and green led leds blink in
alternate sequence
Once done, green led blinks with high pitch
sound indicating successful operation
Programming mode is entered by pressing
the '#' key followed by the default PIN and
then pressing '#' again. Any command will
exit back to keypad programming mode if
the lock is idle for 5 seconds. The keypad
programming mode is itself exited when no
key is pressed for 5 seconds.
Green led and high pitch sound on success.
Must change default pin to enter
construction mode.
The construction PIN is always 8 digits.
Once entered, the green led turns on with a
high pitch on success.
Upon factory reset, the communication key
is set to 16 zeros.
Important:
date/time be set correctly. The date, time
and time zone must be set properly because
the card-connected credentials rely on them.
Once in access mode, invalid time settings
20
20/37
It is extremely important that the

Advertisement