  • Page 1 E - PLEX 5x70 Series ® Stand-Alone Access Controller Installation Instructions...
  • Page 2: Table Of Contents

    Warning and Cautions IMPORTANT: Carefully inspect windows, doorframes, door, lights, etc. to ensure that the recommended procedures will not cause any damage. Kaba Access Control's warranty does not cover damages caused by installation. CAUTION: Wear safety glasses during installation. TOOLS REQUIRED • Electric Drill/Screwdriver with Variable Speed and Torque...
  • Page 3 SK3193 Sh2 of 2 01Aug08 jre, for She Power Interface Unit, Standalone Access Control 03Mar10 jre show R...
  • Page 4: A-1. Wall Installation

    A-1. WALL INSTALLATION Please place the template (located in the middle of this A-1.1 manual) on mounting surface to ensure that there are no obstructions; this allows the keypad housing to be moved up, then in and down onto the base plate. Mark and drill four holes for wood screws, wall anchors, or masonry screws and a ⁄...
  • Page 5: A-2. Gang Box Installation

    A-2. GANG BOX INSTALLATION Mount Gang Box on the wall referring to the Template to A-2.1 insure clearance above the box. This allows the Keypad Housing to be moved up, then in and down onto the Baseplate. Mark and drill holes for wood screws, wall anchors, or masonry screws and a ⁄...
  • Page 6: System Components

    B. SYSTEM COMPONENTS Kaba’s E-Plex Stand-Alone Access Controller consists of the Access Control Unit (ACU) and the Power Interface Unit (PIU). It is typically used in conjunction with an off-the shelf door controller or power extender (not included) connected to either a magnetic lock or electric strike for securing doors or a parking gate for access control of parking areas.
  • Page 7 Kaba Access Control warrants this product to be free from defects in material and workmanship under normal use and service for a period of three (3) years. Kaba Access Control will repair or replace, at our discre- tion, locks found by Kaba Access Control analysis to be defective during this period.
  • Page 8 For your records Model No.: Date Purchased: Dealer: Name: Telephone: Notes For technical assistance please call 1.800.849.TECH (8324) or 336.725.1331...
  • Page 10 7.000 7.000 1.250 1.250 4.000 4.000 1.531 1.531 3.250 3.250 .750 .750 1.500 1.500 3.000 3.000...
  • Page 11 BACK OF THE BOX INTO THE WALL HOLE, USE 2 #6 FLAT HEAD SCREWS TO GO BACK OF THE BOX INTO THE WALL HOLE, USE 2 #6 FLAT HEAD SCREWS TO GO THROUGH THE ACU’S BASE HOLES THEN THROUGH THE BLANK COVER INTO THROUGH THE ACU’S BASE HOLES THEN THROUGH THE BLANK COVER INTO THE SINGLE GANG BOX HOLES. (SCREWS NOT PROVIDED) AFTER THE SAC BASE THE SINGLE GANG BOX HOLES. (SCREWS NOT PROVIDED) IS SCREWED INTO PLACE, PRESS THE RUBBER BUMPER INTO THE SAC BASE HOLE TO ADHERE TO THE SUPPLIED SHIM PLATE BEFORE YOU SLIDE THE KEY- PAD HOUSING ONTO IT’S BASE. KABA ACCESS CONTROL TEMPLATE FOR 1.750 KABA ACCESS CONTROL MOUNTING THE TEMPLATE FOR ACCESS CONTROLLER (ACU) UNIT MOUNTING THE ACCESS CONTROLLER (ACU) UNIT 3.281 1/2" HOLE FOR CABLE WHEN NOT MOUNTING TO AN OUTLET BOX, USE THESE 4 HOLE POSITIONS, WHEN NOT MOUNTING TO AN OUTLET BOX, USE THESE 4 HOLE POSITIONS, ‘W’, TO LOCATE DRILL POINTS FOR WALL ANCHORS THAT USE #10 FLAT HEAD ‘W’, TO LOCATE DRILL POINTS FOR WALL ANCHORS THAT USE #10 FLAT HEAD...
  • Page 15 The PIU requires a four (4) wire interface from the door controller. Two wires provide +12 or +24 VDC to the power interface unit and two wires support normally open (N.O.), or normally closed (N.C.) CONTACT closure from the power interface unit.
  • Page 16 Each of the wire colors is labeled on the PIU’s interface board assembly next to the connector J9 (See Figure 2). The standard cable length is 1.5 feet. Typical installation will have Kaba’s ACU mounted on the unsecured side of the wall next to the door controlled.
  • Page 17: Tamper And Security Features

    D. TAMPER AND SECURITY FEATURES Kaba’s Stand-Alone Access Controller has features built in that can provide an extra layer of security to the installation. The Shim Plate installed between the ACU and mounting surface has a bump that extends through a hole in the Backplate. This bump depresses a security switch in the controller to indicate that the installation is secure.
  • Page 18: Software Setting

    E. SOFTWARE SETTINGS When configuring the E5070 series SAC using the optional Standard Software, choose the check-box or setting that contains “Entry Lock with Passage (Cylindrical or Mortise without Deadbolt)” during lock setup in the software. When configuring the E5270/5770 series SAC using the mandatory ACS Software, select the “Cylindrical or Mortise without Deadbolt”...
  • Page 19 Figure 3 PURPLE YELLOW Notes For technical assistance please call 1.800.849.TECH (8324) or 336.725.1331...
  • Page 20 Kaba ADS Americas 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849.8324 (336) 725.1331 Fax: (800) 346.9640 (336) 725.3269 PKG3239 0410 www.kabaaccess.com...