Access Mode; Bootloader Mode - Kaba E-Plex 5900 User Manual

Card connect lock
Hide thumbs Also See for E-Plex 5900:
Table of Contents

Advertisement

Set date and time
o
Set passage mode
o
Configure the lock using an admin card
o
Set lockout
o
Run diagnostics and display various states of the lock
o
Enter communication mode
o
Reset the lock to factory mode
In the construction mode user cards will not be recognized by the lock.

3.3 Access mode

Once the lock is configured using the admin card, the lock enters the "card connect" access mode and the
construction PIN will not work anymore. In this mode the user can:
Unlock the lock by presenting a valid credential (an ISO 14443A compliant DESFire card or optionally
entering a user PIN followed by the card).
Communicate with the maintenance unit using the configured communication key to access the following
functionalities (requires maintenance unit privilege):
Set the date/time, daylight saving time info and time zone
o
Update the bootloader
o
Update the firmware
o
Use one of the following keypad commands
Set date and time (requires keypad programming privilege)
o
Set passage mode (requires passage mode privilege)
o
Configure the lock using an admin card (requires admin card privilege)
o
Set lockout (requires lockout privilege)
o
Perform diagnostics and display lock's various states (requires lock keypad programming
o
privilege)
Enter communication mode (requires maintenance unit privilege)
o
Reset the lock to factory mode
In this mode cards are required to unlock the lock.

3.4 Bootloader mode

The bootloader mode is a transition mode when updating the lock firmware. Before starting a lock firmware
update, the lock automatically switches to this mode. It remains active until a new firmware is fully received by the
lock. Should the firmware upload be interrupted (communication failure), the lock remains in bootloader mode.
Whenever a key is pressed, the green and red leds will blink sequentially while waiting for a maintenance unit
connection. If no connection is established within 15 seconds, the leds are turned off and the lock waits for
another key press.